ADTRAN

TDU 120AC

Card Type T1 DSU/CSU
Chip Set Unidentified
I/O Options Test jacks - in (2), test jacks - out (2), test jacks - monitor (4), RJ-48 control ports (3), T1 network interface via RJ-48, V.35 port
T1 Data Rate 1.544Mbps
Line Coding AMI, B8ZS
Framing D4, ESF
Data Bus External


wpeE4.jpg (45187 bytes)

CONNECTIONS

Function

Label

Function

Label

T1 network port via RJ-48

CN1

Test jack - out

CN9

Control port - chain in via RJ-48

CN2

Test jack - monitor

CN10

Control port - chain out via RJ-48

CN3

Test jack - in

CN11

DSX-1 DTE port CN4 Test jack - out

CN12

V.35 port

CN5

Test jack - monitor

CN13

Control port - chain in via RJ-48 CN6 Test jack - monitor

CN14

Test jack - monitor CN7 Reset switch SW1
Test jack - in CN8    


DIAGNOSTIC LED(S)

LED

Color

Status

Condition

AIS Red On Unframed all ones being received at the network interface
AIS Red Off Unframed all ones not being received at the network interface

ALM1

Red

On

Alarm condition has been detected on DSU port 1

ALM1

Red

Off

Alarm condition has not been detected on DSU port 1

ALM2

Red

On

Alarm condition has been detected on DSU port 2

ALM2

Red

Off

Alarm condition has not been detected on DSU port 2

ALM3

Red

On

Alarm condition has been detected on Module port 1

ALM3

Red

Off

Alarm condition has not been detected on Module port 1

ALM4

Red

On

Alarm condition has been detected on Module port 2

ALM4

Red

Off

Alarm condition has not been detected on Module port 2

ALM5

Red

On

Alarm condition has been detected on Module port 3

ALM5

Red

Off

Alarm condition has not been detected on Module port 3

ALM6

Red

On

Alarm condition has been detected on Module port 4

ALM6

Red

Off

Alarm condition has not been detected on Module port 4

LOS

Red

On

Network signal is lost

LOS

Red

Off

Network signal is not lost

OK1

Green

On

CSU is operating in normal mode. No errors have been detected

OK1

Green

Off

CSU is not in normal mode, or errors have been detected

OK2

Green

On

DSU port 1 is operating in normal mode. No errors have been detected

OK2

Green

Off

DSU port 1 is not in normal mode, or errors have been detected

OK3

Green

On

DSU port 2 is operating in normal mode. No errors have been detected

OK3

Green

Off

DSU port 2 is not in normal mode, or errors have been detected

OK4

Green

On

Module port 1 is operating in normal mode. No errors have been detected

OK4

Green

Off

Module port 1 is not in normal mode, or errors have been detected

OK5

Green

On

Module port 2 is operating in normal mode. No errors have been detected

OK5

Green

Off

Module port 2 is not in normal mode, or errors have been detected

OK6

Green

On

Module port 3 is operating in normal mode. No errors have been detected

OK6

Green

Off

Module port 3 is not in normal mode, or errors have been detected

OK7

Green

On

Module port 4 is operating in normal mode. No errors have been detected

OK7

Green

Off

Module port 4 is not in normal mode, or errors have been detected

RED

Red

On

Unable to frame to data coming in the network interface

RED

Red

Off

Able to frame to data coming in the network interface

TST1

Yellow

On

CSU is conducting a test

TST1

Yellow

Off

CSU is not conducting a test

TST2

Yellow

On

DSU port 1 is conducting a test

TST2

Yellow

Off

DSU port 1 is not conducting a test

TST3

Yellow

On

DSU port 2 is conducting a test

TST3

Yellow

Off

DSU port 2 is not conducting a test

TST4

Yellow

On

Module port 1 is conducting a test

TST4

Yellow

Off

Module port 1 is not conducting a test

TST5

Yellow

On

Module port 2 is conducting a test

TST5

Yellow

Off

Module port 2 is not conducting a test

TST6

Yellow

On

Module port 3 is conducting a test

TST6

Yellow

Off

Module port 3 is not conducting a test

TST7

Yellow

On

Module port 4 is conducting a test

TST7

Yellow

Off

Module port 4 is not conducting a test

YEL Yellow On Remote alarm indication is being received from network
YEL Yellow Off Remote alarm indication is not being received from network