ADTRAN

HSU 600

Card Type T1 DSU/CSU
Chip Set Unidentified
I/O Options Test jack - in, test jack - out, test jack - monitor, RJ-48 control ports (2), HDSL T1 network interface via RJ-48
T1 Data Rate 1.544Mbps
Line Coding Unidentified
Framing ESF
Data Bus External



CONNECTIONS

Function

Label

Function

Label

HDSL T1 network port via RJ-48

CN1

Test jack - monitor

CN4

Test jack - in

CN2

Control port - chain in via RJ-48

CN5

Test jack - out

CN3

Control port - chain out via RJ-48

CN6


DIAGNOSTIC LED(S)

LED

Color

Status

Condition

ALM

Red

On

Alarm condition has been detected on network

ALM

Red

Off

Alarm condition has not been detected on network

ALM1

Red

On

Alarm condition has been detected on Module 1

ALM1

Red

Off

Alarm condition has not been detected on Module 1

ALM2

Red

On

Alarm condition has been detected on Module 2

ALM2

Red

Off

Alarm condition has not been detected on Module 2

ALM3

Red

On

Alarm condition has been detected on Module 3

ALM3

Red

Off

Alarm condition has not been detected on Module 3

ALM4

Red

On

Alarm condition has been detected on Module 4

ALM4

Red

Off

Alarm condition has not been detected on Module 4

ALM5

Red

On

Alarm condition has been detected on Module 5

ALM5

Red

Off

Alarm condition has not been detected on Module 5

ALM6

Red

On

Alarm condition has been detected on Module 6

ALM6

Red

Off

Alarm condition has not been detected on Module 6

ERR

Unidentified

On

Error has been detected on network. Errors include: BPV, OOF or CRC

ERR

Unidentified

Off

Error has not been detected on network

OK

Green

On

CSU is operating in normal mode. No errors have been detected

OK

Green

Off

CSU is not in normal mode, or errors have been detected

OK1

Green

On

Module 1 is operating in normal mode. No errors have been detected

OK1

Green

Off

Module 1 is not in normal mode, or errors have been detected

OK2

Green

On

Module 2 is operating in normal mode. No errors have been detected

OK2

Green

Off

Module 2 is not in normal mode, or errors have been detected

OK3

Green

On

Module 3 is operating in normal mode. No errors have been detected

OK3

Green

Off

Module 3 is not in normal mode, or errors have been detected

OK4

Green

On

Module 4 is operating in normal mode. No errors have been detected

OK4

Green

Off

Module 4 is not in normal mode, or errors have been detected

OK5

Green

On

Module 5 is operating in normal mode. No errors have been detected

OK5

Green

Off

Module 5 is not in normal mode, or errors have been detected

OK6

Green

On

Module 6 is operating in normal mode. No errors have been detected

OK6

Green

Off

Module 6 is not in normal mode, or errors have been detected

REMOTE

Unidentified

On

Unit is being accessed remotely by PC program

REMOTE

Unidentified

Off

Unit is not being accessed remotely by PC program

TST

Yellow

On

CSU is conducting a test

TST

Yellow

Off

CSU is not conducting a test

TST1

Yellow

On

Module 1 is conducting a test

TST1

Yellow

Off

Module 1 is not conducting a test

TST2

Yellow

On

Module 2 is conducting a test

TST2

Yellow

Off

Module 2 is not conducting a test

TST3

Yellow

On

Module 3 is conducting a test

TST3

Yellow

Off

Module 3 is not conducting a test

TST4

Yellow

On

Module 4 is conducting a test

TST4

Yellow

Off

Module 4 is not conducting a test

TST5

Yellow

On

Module 5 is conducting a test

TST5

Yellow

Off

Module 5 is not conducting a test

TST6

Yellow

On

Module 6 is conducting a test

TST6

Yellow

Off

Module 6 is not conducting a test


MISCELLANEOUS TECHNICAL NOTES

If a DTE timing interface is used, it must be installed in slot 1.  If a DBU interface is used, it must be installed in slot 2.   If a secondary Network interface is used, it must be installed in slot 6.