ADTRAN
HSU 600
Card Type | T1 DSU/CSU |
Chip Set | Unidentified |
I/O Options | Test jack - in, test jack - out, test jack - monitor, RJ-48 control ports (2), HDSL T1 network interface via RJ-48 |
T1 Data Rate | 1.544Mbps |
Line Coding | Unidentified |
Framing | ESF |
Data Bus | External |
CONNECTIONS |
|||
Function |
Label |
Function |
Label |
HDSL T1 network port via RJ-48 | CN1 |
Test jack - monitor | CN4 |
Test jack - in | CN2 |
Control port - chain in via RJ-48 | CN5 |
Test jack - out | CN3 |
Control port - chain out via RJ-48 | CN6 |
DIAGNOSTIC LED(S) |
|||
LED |
Color |
Status |
Condition |
ALM |
Red |
On |
Alarm condition has been detected on network |
ALM |
Red |
Off |
Alarm condition has not been detected on network |
ALM1 |
Red |
On |
Alarm condition has been detected on Module 1 |
ALM1 |
Red |
Off |
Alarm condition has not been detected on Module 1 |
ALM2 |
Red |
On |
Alarm condition has been detected on Module 2 |
ALM2 |
Red |
Off |
Alarm condition has not been detected on Module 2 |
ALM3 |
Red |
On |
Alarm condition has been detected on Module 3 |
ALM3 |
Red |
Off |
Alarm condition has not been detected on Module 3 |
ALM4 |
Red |
On |
Alarm condition has been detected on Module 4 |
ALM4 |
Red |
Off |
Alarm condition has not been detected on Module 4 |
ALM5 |
Red |
On |
Alarm condition has been detected on Module 5 |
ALM5 |
Red |
Off |
Alarm condition has not been detected on Module 5 |
ALM6 |
Red |
On |
Alarm condition has been detected on Module 6 |
ALM6 |
Red |
Off |
Alarm condition has not been detected on Module 6 |
ERR |
Unidentified |
On |
Error has been detected on network. Errors include: BPV, OOF or CRC |
ERR |
Unidentified |
Off |
Error has not been detected on network |
OK |
Green |
On |
CSU is operating in normal mode. No errors have been detected |
OK |
Green |
Off |
CSU is not in normal mode, or errors have been detected |
OK1 |
Green |
On |
Module 1 is operating in normal mode. No errors have been detected |
OK1 |
Green |
Off |
Module 1 is not in normal mode, or errors have been detected |
OK2 |
Green |
On |
Module 2 is operating in normal mode. No errors have been detected |
OK2 |
Green |
Off |
Module 2 is not in normal mode, or errors have been detected |
OK3 |
Green |
On |
Module 3 is operating in normal mode. No errors have been detected |
OK3 |
Green |
Off |
Module 3 is not in normal mode, or errors have been detected |
OK4 |
Green |
On |
Module 4 is operating in normal mode. No errors have been detected |
OK4 |
Green |
Off |
Module 4 is not in normal mode, or errors have been detected |
OK5 |
Green |
On |
Module 5 is operating in normal mode. No errors have been detected |
OK5 |
Green |
Off |
Module 5 is not in normal mode, or errors have been detected |
OK6 |
Green |
On |
Module 6 is operating in normal mode. No errors have been detected |
OK6 |
Green |
Off |
Module 6 is not in normal mode, or errors have been detected |
REMOTE | Unidentified |
On |
Unit is being accessed remotely by PC program |
REMOTE | Unidentified |
Off |
Unit is not being accessed remotely by PC program |
TST |
Yellow |
On |
CSU is conducting a test |
TST |
Yellow |
Off |
CSU is not conducting a test |
TST1 |
Yellow |
On |
Module 1 is conducting a test |
TST1 |
Yellow |
Off |
Module 1 is not conducting a test |
TST2 |
Yellow |
On |
Module 2 is conducting a test |
TST2 |
Yellow |
Off |
Module 2 is not conducting a test |
TST3 |
Yellow |
On |
Module 3 is conducting a test |
TST3 |
Yellow |
Off |
Module 3 is not conducting a test |
TST4 |
Yellow |
On |
Module 4 is conducting a test |
TST4 |
Yellow |
Off |
Module 4 is not conducting a test |
TST5 |
Yellow |
On |
Module 5 is conducting a test |
TST5 |
Yellow |
Off |
Module 5 is not conducting a test |
TST6 |
Yellow |
On |
Module 6 is conducting a test |
TST6 |
Yellow |
Off |
Module 6 is not conducting a test |
MISCELLANEOUS TECHNICAL NOTES |
I f a DTE timing interface is used, it must be installed in slot 1. If a DBU interface is used, it must be installed in slot 2. If a secondary Network interface is used, it must be installed in slot 6. |