ADTRAN

DSU 5600

Card Type CSU/DSU modem
I/O Options RJ-48S, RS-232
Maximum Modem Rate 64Kbps
Data Bus External


CONNECTIONS

Function

Label

Function

Label

RJ-48S connector

CN1

Test selector button

SW1

RS-232 port

CN2

Test activator button

SW2


USER CONFIGURABLE SETTINGS

Setting

Label

Position

  56KBps operation SW3/4 Off
  64KBps operation SW3/4 On
» Clear to Send follows Request to Send SW3/5 Off
  Clear to Send forced on SW3/5 On
» Carrier Detect on only when data is received SW3/6 Off
  Carrier Detect forced on SW3/6 On
» Data Set Ready is off when the network is down or test is in progress SW3/7 On
  Data Set Ready forced on SW3/7 Off
  V.54 Remote Digital Loopback enabled SW3/8 Off
  V.54 Remote Digital Loopback disabled SW3/8 On


DTE CONTROL

Setting

SW3/1

SW3/2

SW3/3

1.2/2.4KBps asynchronous Off Off Off
4.8KBps asynchronous Off On Off
9.6KBps asynchronous On On Off
19.2KBps asynchronous Off Off On
38.4KBps asynchronous On Off On
57.6KBps asynchronous Off On On
Synchronous, scrambler enabled On On On
Synchronous, scrambler disabled On Off Off


DIAGNOSTIC LEDS

LED

Color

Status

Condition

LED1

Green

On

Request to send (RS) detected

LED1

Green

Off

Request to send (RS) not detected

LED2

Green

On

Clear to send (CS) detected

LED2

Green

Off

Clear to send (CS) not detected

LED3

Green

On

Data is being transmitted

LED3

Green

Off

Data is not being transmitted

LED4

Green

On

Data is being received

LED4

Green

Off

Data is being not received

LED5

Green

On

Carrier Detected (CD)

LED5

Green

Off

Carrier not Detected (CD)

LED6

Red

On

Problem on local loop or DDS network

LED6

Red

Off

Normal operation on local loop or DDS network

LED7

Yellow

On

DTE test in progress

LED7

Yellow

Blinking

CSU loopback test initiated by telco

LED8

Yellow

On

Loop test initiated by local DSU

LED8

Yellow

Blinking

Loop test initiated by telco

LED9

Yellow

Blinking

Remote loop test initiated by local DSU

LED9

Yellow

On

Remote loop test in progress by telco

LED10

Yellow

On

Pattern generator is being tested

LED11

Red

On

Remote loop test initiated from local DSU

LED11

Red

Blinking

Remote loop test initiated from remote telco