TOSHIBA

T144NW MODEM

Card Type Modem
Chip Set Unidentified
Maximum Modem Rate 14.4Kbps
Maximum Fax Rate 14.4Kbps
Data Modulation Protocol Bell 103/212A
ITU-T V.21, V.22, V.22bis, V.32ter, V.32bis
Fax Modulation Protocol ITU-T V.17, V.21 CH2, V.27ter, V.29
Error Correction/Compression MNP5, V.42, V.42bis
Fax Class I & II
Data Bus PCMCIA


55470

SUPPORTED COMMAND SET

Basic AT Commands

AT, '+++', A/
A, B, E, H, L, M, O, P, Q, T, V, W, X, Y, Z
&C, &F, &G, &M, &P, &R, &T, &V, &W, &Y, &Z

Extended AT Commands

\A, \B, \G, \J, \K, \N, \W
%C, %L, %Q

S Registers

S0, S1, S2, S3, S4, S6, S7, S8, S9, S10, S11, S12, S14, S16, S18, S21, S22, S23, S24, S25, S26
S28, S29, S30, S31, S32, S33, S38, S40, S91, S92, S99
Note: See MHI Help File for full command documentation. Specific S-register information unavailable; S-registers may vary slightly from MHI help file.


PROPRIETARY AT COMMAND SET

AUTO-MODE DETECTION

Type: Configuration
Format: AT [cmds] N n [cmds]
Description: Selects various options for the automatic detection and negotiation of protocols during the handshake process if the modem is communicating with a remote modem of dissimilar speed.

Command

Function

N0

Auto-mode detection disabled. Handshake begins at line speed designated by the S37 register. If S37=0 handshake follows interface speed

N1

Auto-mode detection enabled. Handshake begins at line speed designated by the S37 register. If S37=0 handshake at highest possible speed with fallback to lower speed if necessary


AUXILIARY RELAY CONTROL

Type: Configuration
Format: AT [cmds] &J [cmds]
Description: Controls auxiliary relay

Command

Function

&J0

Auxiliary relay remains open


CLOCK SOURCE - SYNCHRONOUS TRANSMIT

Type: Configuration
Format: AT [cmds] &X n [cmds]
Description: Selects DTE transmit clock source

Command

Function

&X0

Modem generates clock

&X1

Returns OK

&X2

Returns OK


COMMUNICATION PROTOCOLS

Type: Configuration
Format: AT [cmds] F n [cmds]
Description: Selects the communication protocol for data calls

Command

Protocol

»

F0

Auto-mode detection enabled

F1

V.21 or Bell 103

F2

Reserved

F3

V.23

F4

V.22 at 1200bps

F5

V.22

F6

V.32 or V.32bis at 4800bps

F7

V.32bis at 7200bps

F8

V.32 or V.32bis at 9600bps

F9

V.32bis at 12.0Kbps

F10

V.32bis at 14.4Kbps


COMMUNICATIONS MODE

Type: Configuration
Format: AT [cmds] &Q n [cmds]
Description: Selects communications mode options

Command

Mode

 

&Q0

Asynchronous mode, serial port speed follows connect speed.
»

&Q5

Error correction mode
 

&Q6

Buffered asynchronous mode


DATA SET READY (DSR)

Type: Configuration
Format: AT [cmds] &S n [cmds]
Description: Selects DSR options

Command

Function

&S0

DSR forced high

&S1

DSR high only while modem is handshaking or connected


DATA TERMINAL READY (DTR)

Type: Configuration
Format: AT [cmds] &D n [cmds]
Description: Selects modem response to DTR
Note: The action each variant of &D causes depends on the setting of &Q

&Q Setting

&D0

&D1

&D2

&D3

&Q0, &Q5, &Q6

Command 0

Command 1

Command 2

Command 4

&Q1, &Q4

Command 2

Command 1

Command 2

Command 4

&Q2, &3

Command 2

Command 2

Command 2

Command 2

Command

Function

Command 0

Modem does not respond to DTR

Command 1

Modem goes to command mode after DTR goes is off

Command 2

Modem goes to command mode and disconnects (hangs up) after DTR goes off; Auto-Answer is disabled.

Command 3

Modem is initialized after DTR goes off


DIAL

Type: Immediate
Format: AT [cmds] D<#> [cmds]
Description: Dials telephone number according to any modifiers included in the string
Note: Any combination of modifiers can be used to produce the desired dial functions in sequence.

Command

Function

DL

Re-dial last number

DP

Pulse dialing enabled

DR

Answer mode enabled; originate mode disabled following handshake initiation.

DS=n

Dial stored telephone number n

DT

Tone dialing enabled/Pulse dialing disabled

DW

Dialing resumed following dial tone detection

D,

Dialing paused for amount of time specified in S8 register

D!

Flash function initiated. Modem commanded to go off-hook for specified time before returning on-hook.

D@

Wait for Quite Answer function enabled. Modem waits until a "quiet answer," a ring-back signal followed by silence up to the time specified in S7, is received prior to executing the rest of the dial string.

D^

1800Hz periodic calling tone enabled in originate mode. (Europe)

D;

Modem returned to idle state after dialing. The semicolon can only be placed at the end of the dial command.


FLOW CONTROL

Type: Configuration
Format: AT [cmds] &K n [cmds]
Description: Enables flow control options

Command

Function

&K0

Flow control disabled

&K3

RTS/CTS flow control enabled

&K4

XON/XOFF flow control enabled

&K5

Transparent XON/XOFF flow control enabled

&K6

Both RTS/CTS & XON/XOFF flow control enabled


LINE TYPE

Type: Configuration
Format: AT [cmds] &L n [cmds]
Description: Selects line type

Command

Line Type

&L0

Switched line (PSTN/Dial-up)


REPORT INFORMATION

Type: Immediate
Format: AT [cmds] I n [cmds]
Description: Displays information requested

Command

Function

I0

Reports product code

I1

Reports ROM checksum

I2

Tests and reports ROM checksum

I3

Reports firmware version and application codes

I4

Reports OEM identifier string in either binary or ASCII format

I5

Reports country code

I6

Reports data pump model and internal code


TRANSMIT CARRIER

Type: Configuration
Format: AT [cmds] C n [cmds]
Description: Controls the transmit carrier switching

Command

Function

C1

Transmit carrier enabled


EXTENDED AT COMMANDS

AUTO-RETRAIN - AUTO-FALLBACK/FALL-FORWARD

Type: Configuration
Format: AT [cmds] %E n [cmds]
Description: Controls auto-retrain mode and fallback/fall-forward

Command

Function

%E0

Auto-retrain disabled

%E1

Auto-retrain enabled


V.23 MODE

Type: Configuration
Format: AT [cmds] %F n [cmds]
Description: Selects V.23 split-speed and half-duplex

Command

Function

 

%F1

75bps transmit, 1200bps receive (split-speed)
»

%F2

1200bps transmit, 75bps receive (split-speed)


S(STATUS) -REGISTERS

BIT-MAPPED REGISTER S27

Format AT [cmds] S27= n [cmds]
Range: 0-111
Unit: Bit-mapped
Description: Selects synchronous/asynchronous mode, line type, clock source, and ITU-T/Bell modes.

Bit

Value

Function

1, 0

000

001

010

011

101

110

Asynchronous mode, serial port speed follows connect speed

Asynchronous off-line command mode and synchronous connect mode

Asynchronous off-line command mode; modem autodials first number in directory, then synchronous connect mode

Not supported

Synchronous error correction

Synchronous operation in normal mode

2

0

1

Switched line

Leased line

3

0

Not Used

5, 4

00

01

10

Local modem generates transmit clock source

Local DTE generates transmit clock source

Remote DCE/DTE generates transmit clock source

6

0

1

ITU/T mode

Bell mode


BIT-MAPPED REGISTER S41

Format AT [cmds] S41= n [cmds]
Range: 0-31
Unit: Bit-mapped
Description: Selects compression, auto-retrain, flow control, and MNP mode.

Bit

Value

Function

1 - 0

00

01

10

11

Data compression disabled

MNP5 enabled

V.42bis enabled

MNP5 and V.42bis enabled

2

0

1

Auto-retrain disabled

Auto-retrain enabled

3

0

1

Flow control disabled

Flow control enabled

4

0

1

Stream mode for MNP

Block mode for MNP

5-7

0

Not Used


BREAK OPTIONS

Type: Register
Format AT [cmds] S82= n [cmds]
Description: Sets the method for break transmission during error-control and ASB connections.

Command

Function

S82=3

Expedited signaling, immediately send timed break

S82=7

Destructive signaling, buffers cleared, immediately send timed break

S82=128

In-sequence signaling, timed break sent in sequence with transmitted data


CONNECTION FAILURE CODES

Type: Register
Format AT [cmds] S86? [cmds]
Description: Reports codes which correspond to the possible causes of a connection failure

Value

Meaning

0

Normal hang up

4

Carrier signal lost

5

No error-control detected for remote modem during feature negotiation

9

No common protocol found

12

No failure - remote modem disconnected normally

13

Remote modem failed to respond after 10 re-transmissions same message

14

Violation of negotiated protocol caused failure


DCE LINE SPEED

Type: Register
Format AT [cmds] S37= n [cmds]
Description: Sets the maximum allowable data exchange rate attempted during handshake process.

Command

Function

S37=0

Speed of last connection

S37=1

300bps

S37=2

300bps

S37=3

300bps

S37=5

1200bps

S37=6

2400bps

S37=7

V.23 at 75/1200Kbps


ERROR CORRECTION NEGOTIATION

Type: Register
Format AT [cmds] S36= n [cmds]
Description: Selects the action of the modem if it fails to connect with the error-correction protocol set in &Q.

Command

Function

S36=0

Hang up

S36=1

Attempt a direct connection

S36=3

Attempt a buffered connection

S36=4

Attempt a connection at MNP2-4; if that fails, hang up.

S36=5

Attempt a connection at MNP2-4; if that fails, attempt a direct connection.

S36=7

Attempt a connection at MNP2-4; if that fails, attempt a buffered connection.


ERROR CORRECTION/COMPRESSION

Type: Register
Format: AT [cmds] S46= n [cmds]
Description: Selects active error correction and compression protocols

Command

Function

S46=136

LAPM only, no compression

S46=138

LAPM with V.42bis data compression


EXTENDED RESULT CODES

Type: Register
Format AT [cmds] S95= n [cmds]
Range: 0-255
Unit: Bit-mapped
Description: Works in combination with the W n command to enable extended result codes. Features enabled by S95 take precedence over the options selected by W n .

Bit

Value

Function

0,1

0

Not used

2

0

1

COMPRESSION result codes disabled.

COMPRESSION result codes enabled.

3

0

Not used

4

0

1

PROTOCOL result codes disabled.

PROTOCOL result codes enabled.

5

0

1

CARRIER result codes disabled.

CARRIER result codes enabled.

6

0

1

Verbose CONNECT result codes display DTE or line speed only.

Adds "/ARQ" to all verbose CONNECT result codes except "NONE."

7

0

1

CONNECT result code reports DTE speed.

CONNECT result code reports line speed instead DTE speed.


FEATURE NEGOTIATION OPTIONS

Type: Register
Format: AT [cmds] S48= n [cmds]
Description: Selects active error correction and compression protocols

Command

Function

S48=0

Detection negotiation disabled, XID negotiation disabled

S48=7

Detection negotiation and XID negotiation enabled

S48=128

Fall-back to options set in S36


FLOW CONTROL

Type: Register
Format AT [cmds] S39? [cmds]
Description: Displays the current flow control

Value

Meaning

0

Flow control disabled

3

RTS/CTS flow control enabled

4

XON/XOFF flow control enabled

5

Both RTS/CTS & XON/XOFF flow control enabled


SOFT-SWITCH FUNCTIONS

Type: Register
Format AT [cmds] S80 [cmds]
Description: Further information is currently unavailable