VIKING COMPONENTS

33.6K/56K PC CARD MODEM

Card Type Modem
Chip Set Unidentified
Maximum Modem Rate 56.0Kbps
Maximum Fax Rate Unidentified
Data Modulation Protocol Bell 103/212A
V.21, V.22, V.22bis, V.23, V.32, V.32bis, V.34, K56flex
Fax Modulation Protocol Unidentified
Error Correction/Compression MNP5, V.42, V.42bis
Fax Class Class I & II
Data Bus PCMCIA


55341

SUPPORTED COMMAND SET

Basic AT Commands

AT, ‘+++’, A/
A, E, H, M, O, X, V, W, Z
&M, &R, &V, &W, &Y, &Z

Extended AT Commands

%E

S Registers

S0, S1, S2, S3, S4, S5, S6, S7, S8, S9, S10, S11, S24, S32, S33

Special Commands

#CID
Note: Please see MHI Help file for full command documentation.


Proprietary AT Command Set

COMMUNICATIONS MODE

Type: Configuration
Format: AT [cmds] &Q n [cmds]
Description: Selects communications mode options

Command

Mode

&Q0

Asynchronous mode, serial port speed follows connect speed.

&Q1

Asynchronous off-line command mode and synchronous connect mode.

&Q2

Asynchronous off-line command mode - modem autodials first number in directory, then synchronous connect mode.

&Q3

Asynchronous off-line command mode on low DTR, synchronous connect mode on high DTR.

&Q5

Error correction mode

&Q6

Buffered asynchronous mode


DIAL

Type: Immediate
Format: AT [cmds] D<#> [cmds]
Description: Dials telephone number according to any modifiers included in the string
Note: Any combination of modifiers can be used to produce the desired dial functions in sequence.

Command

Function

DL

Re-dial last number

DP

Pulse dialing enabled

DS=n

Dial stored telephone number n

DT

Tone dialing enabled/Pulse dialing disabled

DW

Dialing resumed following dial tone detection

D,

Dialing paused for amount of time specified in S8 register

D!

Flash function initiated. Modem commanded to go off-hook for specified time before returning on-hook.

D@

Wait for Quiet Answer function enabled. Modem waits until a "quiet answer," a ring-back signal followed by silence up to the time specified in S7, is received prior to executing the rest of the dial string.

D&

Calling card "Bong" detection enabled. Waits for credit card dialing tone for amount of time specified by the S7 command.

D;

Modem returned to idle state after dialing. The semicolon can only be placed at the end of the dial command.

D^

Enables/disbables calling tone


FACTORY DEFAULT PROFILE

Type: Configuration
Format: AT [cmds] &F [cmds]
Description: Sets values in active profile to values found in the default profile

Command

Function

&F0

Restore factory configuration 0

&F1

Restore factory configuration 1


FLOW CONTROL

Type: Configuration
Format: AT [cmds] &K n [cmds]
Description: Enables flow control options

Command

Function

 

&K0

Flow control disabled
»

&K3

RTS/CTS flow control enabled
 

&K4

XON/XOFF flow control enabled
 

&K5

Transparent XON/XOFF flow control enabled
 

&K6

Both RTS/CTS and XON/XOFF flow control enabled


REPORT INFORMATION

Type: Immediate
Format: AT [cmds] I n [cmds]
Description: Displays information requested

Command

Function

I0

Reports product code

I1

Reports ROM checksum

I2

Tests and reports ROM checksum

I3

Reports firmware version

I4

Reports manufactuer ID

I5

Reports country code

I6

Reports data pump model and revision code


SPEAKER VOLUME

Type: Configuration
Format: AT [cmds] L n [cmds]
Description: Controls speaker volume

Command

Function

 

L0

Low volume setting
 

L1

Low volume setting
»

L2

Medium volume setting
 

L3

Highest volume setting


SPECIAL COMMANDS

MODULATION SELECTION

Type: Configuration
Format: AT [cmds] +MS= x,y,z,a,b,c [cmds]
Description: Sets options for active protocol; the transfer rates specified by z and a must be valid for the protocol selected.

Command

Function

x=0

V.21

x=1

V.22

x=2

V.22bis

x=3

V.23

x=9

V.32

x =10

V.32bis

x=11

V.34

x=56

K56flex

x =64

Bell 103

x =69

Bell 212A

y =0

Automode disabled

y =1

Auto-detect highest speed enabled

z, a=300

Set minimum or maximum transfer rate at 300bps, respectively.

z, a =1200

Set minimum or maximum transfer rate at 1200bps, respectively.

z, a =2400

Set minimum or maximum transfer rate at 2400bps, respectively.

z, a =4800

Set minimum or maximum transfer rate at 4800bps, respectively.

z, a =7200

Set minimum or maximum transfer rate at 7200bps, respectively.

z, a =9600

Set minimum or maximum transfer rate at 9600bps, respectively.

z, a =12000

Set minimum or maximum transfer rate at 12000bps, respectively.

z, a =14400

Set minimum or maximum transfer rate at 14400bps, respectively.

z, a =16800

Set minimum or maximum transfer rate at 16800bps, respectively.

z, a =19200

Set minimum or maximum transfer rate at 19200bps, respectively.

z, a =21600

Set minimum or maximum transfer rate at 21600bps, respectively.

z, a =24000

Set minimum or maximum transfer rate at 24000bps, respectively.

z, a =26400

Set minimum or maximum transfer rate at 26400bps, respectively.

z, a =28800

Set minimum or maximum transfer rate at 28800bps, respectively.

z, a =33600

Set minimum or maximum transfer rate at 33600bps, respectively.

z, a =56000

Set minimum or maximum transfer rate at 56000bps, respectively.

b =0

µ-law encoding

b= 1

A-law encoding

c =0

Robbed bit signaling disabled

c=1

Robbed bit signaling enabled


DSVD MODE

Type: Configuration
Format: AT [cmds] -SSE= n [cmds]
Description: Select whether the modem will use DSVD mode.

Command

Function

»

-SSE=0

DSVD mode disabled.
 

-SSE=1

DSVD mode enabled.