ADC KENTROX
PACESETTER T1
Card Type | T1/Ethernet/ISDN Router |
Chip Set | Unidentified |
Wiring Type | Unshielded twisted pair |
I/O Options | Power, UTP Ethernet interface via RJ-45 connector, ISDN BRI U interface via RJ-45 connector, T1 network interface via RJ-48C connector, RJ-45 control port |
Ethernet Transfer Rate | 10Mbps |
T1 Transfer Rate | 1.544Mbps |
T1 Modulation Protocol | Frame Relay, PPP, X.25 |
ISDN Data Rate | 128Kbps |
ISDN Modulation Protocol | PPP, MLPPP, X.25 |
Data Bus | External |
CONNECTIONS |
|||
Function |
Label |
Function |
Label |
DC power connector | CN1 |
T1 network interface (RJ-48C) | CN4 |
10 BaseT Ethernet interface (RJ-45) | CN2 |
Control port (RJ-45) | CN5 |
ISDN BRI interface (RJ-45) | CN3 |
DIAGNOSTIC LED(S) |
|||
LED |
Color |
Status |
Condition |
LSTS |
Unidentified |
On |
10 BaseT connection is good |
LSTS |
Unidentified |
Off |
10 BaseT connection is broken |
TD |
Unidentified |
On |
Data is being transmitted on Ethernet interface |
TD |
Unidentified |
Off |
Data is not being transmitted on Ethernet interface |
RD |
Unidentified |
On |
Data is being received on Ethernet interface |
RD |
Unidentified |
Off |
Data is not being received on Ethernet interface |
USTS |
Unidentified |
On |
ISDN connection is good |
USTS |
Unidentified |
Off |
ISDN connection is broken |
DCH |
Unidentified |
On |
D channel is active |
DCH |
Unidentified |
Off |
D channel is inactive |
B1 |
Unidentified |
On |
B-channel 1 data call connected |
B1 |
Unidentified |
Blinking |
B-channel 1 attached device off hook or dialing |
B1 |
Unidentified |
Off |
No activity on B-channel 1 |
B2 |
Unidentified |
On |
B-channel 2 data call connected |
B2 |
Unidentified |
Blinking |
B-channel 2 attached device off hook or dialing |
B2 |
Unidentified |
Off |
No activity on B-channel 2 |
CV |
Unidentified |
On |
Code violation or loss of synchronization detected at the T1 network interface |
CV |
Unidentified |
Off |
Code violation or loss of synchronization not detected at the T1 network interface |
RED |
Unidentified |
On |
Red alarm condition detected on T1 network |
RED |
Unidentified |
Off |
Red alarm condition not detected on T1 network |
YEL |
Unidentified |
On |
Yellow alarm condition detected on T1 network |
YEL |
Unidentified |
Off |
Yellow alarm condition not detected on T1 network |
TST |
Unidentified |
On |
Unit is conducting a test |
TST |
Unidentified |
Off |
Unit is not conducting a test |