RAD DATA COMMUNICATIONS

FCD-T1/2/T1

Card Type T1 CSU/DSU
Chip Set Unidentified
I/O Options AC power connector, 25-pin RS-530 ports (2), serial ports (2), RJ-48 network interface (2)
T1 Transfer Rate 1.544Mbps
T1 Protocol AMI, Transparent, B7ZS, B8ZS
Frame type D4
Data Bus External


CONNECTIONS

Function

Label

Function

Label

AC power connector

CN1

Auxiliary network port via RJ-48 connector

CN5

DTE serial port 1

CN2

Main network port via RJ-48 connector

CN6

25-pin connector - channel 1

CN3

DCE serial port 2

CN7

25-pin connector - channel 2

CN4

Power switch

SW2


USER CONFIGURABLE SETTINGS

Setting

Label

Position

» Signal ground is connected to the frame ground

JP8

Closed

  Signal ground is not connected to the frame ground

JP8

Open

» Front panel push-buttons are enabled

JP77

Pins 1 & 2 closed

  Front panel push-buttons are disabled

JP77

Pins 2 & 3 closed

» Supervisor ports operate according to user-defined parameters

S1/1

Off

  CSU/DSU uses default parameters stored in its EPROM

S1/1

On

  User password enabled

S1/2

Off

» Default password enabled. Password=RAD

S1/2

On

» Loads user-selected parameters from NVRAM on power-up

S1/3

Off

  Loads default parameters stored in its EPROM on power-up

S1/3

On

» Factory configured - do not alter

S1/4

Off


ALARM/RELAY

Function

JP51

JP52

»

Alarm relay is disconnected. DTE serial port 1 (CN2) provides full functionality

Pins 2 & 3 closed

Pins 2 & 3 closed

 

Alarm relay is connected instead of DCD and CTS lines. Polled communication disabled

Pins 1 & 2 closed

Pins 1 & 2 closed


DIAGNOSTIC LED(S)

LED

Color

Status

Condition

RED 1

Unidentified

On

DSU/CSU is detecting a red alarm condition on the main link

RED 1

Unidentified

Off

DSU/CSU is not detecting a red alarm condition on the main link

YEL 1

Unidentified

On

DSU/CSU is detecting a yellow alarm condition on the main link

YEL 1

Unidentified

Off

DSU/CSU is not detecting a yellow alarm condition on the main link

RED 2

Unidentified

On

DSU/CSU is detecting a red alarm condition on the sub link

RED 2

Unidentified

Off

DSU/CSU is not detecting a red alarm condition on the sub link

YEL 2

Unidentified

On

DSU/CSU is detecting a yellow alarm condition on the sub link

YEL 2

Unidentified

Off

DSU/CSU is not detecting a yellow alarm condition on the sub link

ALM

Unidentified

On

DSU/CSU is detecting an alarm condition in the system

ALM

Unidentified

Off

DSU/CSU is not detecting an alarm condition in the system

TST

Unidentified

On

DSU or CSU loopback test active

TST

Unidentified

Off

DSU or CSU loopback test not running


VER. X.21

CONNECTIONS

Function

Label

Function

Label

15-pin connector - channel 1

CN7

15-pin connector - channel 2

CN8


VER. V.35

CONNECTIONS

Function

Label

Function

Label

34-pin connector - channel 1

CN9

34-pin connector - channel 2

CN10


MISCELLANEOUS TECHNICAL NOTE