NATURAL MICROSYSTEMS CORPORATION

AG-QUAD BOARD

Card Type E1, T1 CSU
NIC Type E1, T1
Maximum Onboard Memory Unidentified
Boot ROM Not available
Network Transfer Rate 1.544Mbps
Topology Star
Wiring Type 75ohm or 120ohm RJ-48C twisted pair copper wire
Data Bus 32-bit PCI


CONNECTIONS

Function

Label

Function

Label

RJ-48 connector to trunk line 1

CN1

RJ-48 connector to trunk line 4

CN4

RJ-48 connector to trunk line 2

CN2

MVIP connector

JP6

RJ-48 connector to trunk line 3

CN3

   


USER CONFIGURABLE SETTINGS

Function

Label

Position

» Factory configured - do not alter

SW2/1-6

Unidentified

» Factory configured - do not alter

SW3/1-6

Unidentified

» Factory configured - do not alter

SW4/1-6

Unidentified

» Factory configured - do not alter

SW5/1-6

Unidentified


MVIP TERMINATION

Function

SW1/1

SW1/2

SW1/3

SW1/4

SW1/5

SW1/6

»

Clock master

Off

Off

Off

Off

Off

Off

 

MVIP termination

On

On

On

On

On

On


DIAGNOSTIC LED(S)

LED

Color

Status

Trunk

Condition

LED1

Green

On

Trunk 1

Proper frame SYNC

LED1

Green

Off

Trunk 1

All ones alarm (AIS), loss of frame, loss of signaling multiframe, or CRC errors detected

LED2

Yellow

On

Trunk 1

Remote loss of frame or remote loss of signaling multiframe

LED2

Yellow

Off

Trunk 1

Remote loss of frame or remote loss of signaling multiframe not detected

LED3

Red

On

Trunk 1

Loss of frame, loss of signal, or bit error

LED3

Red

Off

Trunk 1

Loss of frame, loss of signal, or bit error not detected

LED4

Green

On

Trunk 2

Proper frame SYNC

LED4

Green

Off

Trunk 2

All ones alarm (AIS), loss of frame, loss of signaling multiframe, or CRC errors detected

LED5

Yellow

On

Trunk 2

Remote loss of frame or remote loss of signaling multiframe

LED5

Yellow

Off

Trunk 2

Remote loss of frame or remote loss of signaling multiframe not detected

LED6

Red

On

Trunk 2

Loss of frame, loss of signal, or bit error

LED6

Red

Off

Trunk 2

Loss of frame, loss of signal, or bit error not detected

LED7

Green

On

Trunk 3

Proper frame SYNC

LED7

Green

Off

Trunk 3

All ones alarm (AIS), loss of frame, loss of signaling multiframe, or CRC errors detected

LED8

Yellow

On

Trunk 3

Remote loss of frame or remote loss of signaling multiframe

LED8

Yellow

Off

Trunk 3

Remote loss of frame or remote loss of signaling multiframe not detected

LED9

Red

On

Trunk 3

Loss of frame, loss of signal, or bit error

LED9

Red

Off

Trunk 3

Loss of frame, loss of signal, or bit error not detected

LED10

Green

On

Trunk 4

Proper frame SYNC

LED10

Green

Off

Trunk 4

All ones alarm (AIS), loss of frame, loss of signaling multiframe, or CRC errors detected

LED11

Yellow

On

Trunk 4

Remote loss of frame or remote loss of signaling multiframe

LED11

Yellow

Off

Trunk 4

Remote loss of frame or remote loss of signaling multiframe not detected

LED12

Red

On

Trunk 4

Loss of frame, loss of signal, or bit error

LED12

Red

Off

Trunk 4

Loss of frame, loss of signal, or bit error not detected


MVIP BUS ADAPTER

CONNECTIONS

Function

Label

Function

Label

Header connector to main board

JP1

MVIP-90 cable connector

JP3


MISCELLANEOUS TECHNICAL NOTES

Systems containing an AG-Quad & MVIP-90 boards require a MVIP Bus Adapter to connect the MVIP-90 bus to the H 100 bus