NATURAL MICROSYSTEMS CORPORATION
AG-QUAD BOARD
Card Type | E1, T1 CSU |
NIC Type | E1, T1 |
Maximum Onboard Memory | Unidentified |
Boot ROM | Not available |
Network Transfer Rate | 1.544Mbps |
Topology | Star |
Wiring Type | 75ohm or 120ohm RJ-48C twisted pair copper wire |
Data Bus | 32-bit PCI |
CONNECTIONS |
|||
Function |
Label |
Function |
Label |
RJ-48 connector to trunk line 1 | CN1 |
RJ-48 connector to trunk line 4 | CN4 |
RJ-48 connector to trunk line 2 | CN2 |
MVIP connector | JP6 |
RJ-48 connector to trunk line 3 | CN3 |
USER CONFIGURABLE SETTINGS |
|||
Function |
Label |
Position |
|
» | Factory configured - do not alter | SW2/1-6 |
Unidentified |
» | Factory configured - do not alter | SW3/1-6 |
Unidentified |
» | Factory configured - do not alter | SW4/1-6 |
Unidentified |
» | Factory configured - do not alter | SW5/1-6 |
Unidentified |
MVIP TERMINATION |
|||||||
Function |
SW1/1 |
SW1/2 |
SW1/3 |
SW1/4 |
SW1/5 |
SW1/6 |
|
» | Clock master |
Off |
Off |
Off |
Off |
Off |
Off |
MVIP termination |
On |
On |
On |
On |
On |
On |
DIAGNOSTIC LED(S) |
||||
LED |
Color |
Status |
Trunk |
Condition |
LED1 |
Green |
On |
Trunk 1 |
Proper frame SYNC |
LED1 |
Green |
Off |
Trunk 1 |
All ones alarm (AIS), loss of frame, loss of signaling multiframe, or CRC errors detected |
LED2 |
Yellow |
On |
Trunk 1 |
Remote loss of frame or remote loss of signaling multiframe |
LED2 |
Yellow |
Off |
Trunk 1 |
Remote loss of frame or remote loss of signaling multiframe not detected |
LED3 |
Red |
On |
Trunk 1 |
Loss of frame, loss of signal, or bit error |
LED3 |
Red |
Off |
Trunk 1 |
Loss of frame, loss of signal, or bit error not detected |
LED4 |
Green |
On |
Trunk 2 |
Proper frame SYNC |
LED4 |
Green |
Off |
Trunk 2 |
All ones alarm (AIS), loss of frame, loss of signaling multiframe, or CRC errors detected |
LED5 |
Yellow |
On |
Trunk 2 |
Remote loss of frame or remote loss of signaling multiframe |
LED5 |
Yellow |
Off |
Trunk 2 |
Remote loss of frame or remote loss of signaling multiframe not detected |
LED6 |
Red |
On |
Trunk 2 |
Loss of frame, loss of signal, or bit error |
LED6 |
Red |
Off |
Trunk 2 |
Loss of frame, loss of signal, or bit error not detected |
LED7 |
Green |
On |
Trunk 3 |
Proper frame SYNC |
LED7 |
Green |
Off |
Trunk 3 |
All ones alarm (AIS), loss of frame, loss of signaling multiframe, or CRC errors detected |
LED8 |
Yellow |
On |
Trunk 3 |
Remote loss of frame or remote loss of signaling multiframe |
LED8 |
Yellow |
Off |
Trunk 3 |
Remote loss of frame or remote loss of signaling multiframe not detected |
LED9 |
Red |
On |
Trunk 3 |
Loss of frame, loss of signal, or bit error |
LED9 |
Red |
Off |
Trunk 3 |
Loss of frame, loss of signal, or bit error not detected |
LED10 |
Green |
On |
Trunk 4 |
Proper frame SYNC |
LED10 |
Green |
Off |
Trunk 4 |
All ones alarm (AIS), loss of frame, loss of signaling multiframe, or CRC errors detected |
LED11 |
Yellow |
On |
Trunk 4 |
Remote loss of frame or remote loss of signaling multiframe |
LED11 |
Yellow |
Off |
Trunk 4 |
Remote loss of frame or remote loss of signaling multiframe not detected |
LED12 |
Red |
On |
Trunk 4 |
Loss of frame, loss of signal, or bit error |
LED12 |
Red |
Off |
Trunk 4 |
Loss of frame, loss of signal, or bit error not detected |
MVIP BUS ADAPTER
CONNECTIONS |
|||
Function |
Label |
Function |
Label |
Header connector to main board | JP1 |
MVIP-90 cable connector | JP3 |
MISCELLANEOUS TECHNICAL NOTES |
Systems containing an AG-Quad & MVIP-90 boards require a MVIP Bus Adapter to connect the MVIP-90 bus to the H 100 bus |