RAD DATA COMMUNICATIONS, INC.
FOM-8H/FC
Card Type |
Modem (synchronous/asynchronous) |
Chipset |
Unidentified |
Transfer Rate |
56Kbps/64Kbps |
Data Bus |
V.24, V.35, X.21, or RS-530 serial |
Data Modulation |
Bell 103A/212A |
CONNECTIONS |
|||
Function |
Label |
Function |
Label |
V.24, V.35, X.21, or RS-530 serial port |
CN1 |
Fiber optic FC transmit cable |
CN3 |
Fiber optic FC receive cable |
CN2 |
USER CONFIGURABLE SETTINGS |
|||
Setting |
Label |
Position |
|
» |
Line speed set to 64Kbps |
SW2/4 |
Off |
Line speed set to 56Kbps |
SW2/4 |
On |
|
» |
Stop bit shortened by 25% in asynchronous mode |
SW2/5 |
Off |
Stop bit shortened by 12.5% in asynchronous mode |
SW2/5 |
On |
|
» |
CD signal forced high |
SW3/2 |
On |
CD signal follows RTS |
SW3/2 |
Off |
|
» |
Pin 18 of CN1 has no function |
SW3/3 |
Off |
Pin 18 of CN1 begins local analog loopback test |
SW3/3 |
On |
|
» |
Pin 21 of CN1 has no function |
SW3/4 |
Off |
Pin 21 of CN1 begins remote digital loopback test |
SW3/4 |
On |
TRANSMIT CLOCK SOURCE SELECTION |
||||
Setting |
SW2/1 |
SW2/2 |
SW2/3 |
|
Asynchronous mode |
Off |
On |
Off |
|
» |
Internal clock source |
Off |
Off |
Off |
External clock source |
On |
Off |
Off |
|
Remote clock source |
Off |
Off |
On |
CHARACTER LENGTH SELECTION |
|||
Setting |
SW2/6 |
SW3/1 |
|
8 bits |
Off |
Off |
|
9 bits |
Off |
On |
|
» |
10 bits |
On |
Off |
11 bits |
On |
On |
TEST MODE SELECTION |
||
Setting |
SW1 |
|
Start local analog loopback test |
Position 1 |
|
» |
Normal operation |
Position 2 |
Start remote digital loopback test |
Position 3 |
DIAGNOSTIC LED(S) |
|||
LED |
Color |
Status |
Condition |
TD |
Yellow |
On |
Modem is transmitting data |
TD |
Yellow |
Off |
Modem is not transmitting data |
CD |
Yellow |
On |
Carrier signal detected |
CD |
Yellow |
Off |
Carrier signal not detected |
TST |
Red |
On |
Modem is in test mode |
TST |
Red |
Off |
Modem is not in test mode |
PWR |
Green |
On |
Power is on |
PWR |
Green |
Off |
Power is off |