Patton Electronics Company
1018
Card Type | Modem(synchronous/asynchronous) |
Maximum Data Rate | 57.6Kbps |
Data Bus | External |
Data Modulation Protocol | Proprietary |
V1502
CONNECTIONS |
|||
Function |
Label |
Function |
Label |
Line in | CN1 |
RS-232/422 | CN3 |
DC power | CN2 |
CARRIER SIGNAL |
|
Setting |
SW2/F |
Always on |
Off |
Follows DTR |
On |
CLOCK SOURCE |
||
Setting |
SW2/D |
SW2/E |
Internal transmit |
On |
On |
Receive recover |
Off |
On |
LOCAL ANALOG LOOPBACK TEST |
|
Setting |
SW1/A |
Enabled |
On |
Disabled |
Off |
LOOPBACK TEST SELECT |
|
Setting |
SW4 |
Local analog loopback |
1 |
Normal operation |
2 |
Remote digital loopback |
3 |
SPEED |
||||
Setting |
SW1/E |
SW1/F |
SW1/G |
|
1.2Kbps |
Off |
Off |
Off |
|
2.4Kbps |
On |
Off |
Off |
|
4.8Kbps |
Off |
Off |
On |
|
9.6Kbps |
On |
Off |
On |
|
19.2Kbps |
Off |
On |
Off |
|
28.8Kbps |
On |
On |
Off |
|
38.4Kbps |
Off |
On |
On |
|
» | 57.6Kbps |
On |
On |
On |
REMOTE DIGITAL LOOPBACK TEST |
|
Setting |
SW1/B |
Enabled |
On |
Disabled |
Off |
RESET |
|
Setting |
SW1/D |
Reset |
On |
Normal operation |
Off |
TEST FUNCTIONS |
|
Setting |
SW1/A |
Enabled |
On |
Disabled |
Off |
TEST PATTERN |
|
Setting |
SW3 |
Generate 511/E test pattern |
1 |
Normal operation |
2 |
Test pattern generator |
3 |
FACTORY DEFAULT SETTINGS |
|
Switch |
Setting |
SW1/C |
Not used |
SW2/A |
Not used |
SW2/B |
Not used |
SW2/C |
Not used |
SW2/G |
Off |
SW2/H |
Off |
V.54 |
|
Setting |
SW1/H |
V.54 Disabled |
On |
V.54 Enabled |
Off |
DIAGNOSTIC LED(S) |
|||
LED |
Color |
Status |
Condition |
PWR |
Green |
On |
Power is on |
PWR |
Green |
Off |
Power is off |
TD |
Red |
Blinking |
Modem is transmitting data |
TD |
Red |
Off |
Modem is not transmitting data |
CD |
Red |
On |
Carrier detected |
CD |
Red |
Off |
Carrier not detected |
BERT |
Red |
On |
511/E test pattern on or 511 mode errors detected |
BERT |
Red |
Off |
Normal operation in 511 mode |
LOOP |
Red |
On |
Modem is in loopback test mode |
LOOP |
Red |
Off |
Modem is not in loopback test mode |