SEAGATE TECHNOLOGY, INC.
PYTHON 4LDAT+ (DDS2)
Device Type | Internal Tape Drive |
Interface | SCSI-2 |
Format | DAT (DDS-2) |
Sustained Transfer Rate | 400 KBPS |
Size | 5.25 in. full height |
View | Top |
USER CONFIGURABLE SETTINGS |
|||
Setting |
Label |
Position |
|
» | Termination disabled | JP2 |
Open |
Termination enabled | JP2 |
Closed |
|
» | MRS mode disabled | SW1/4 |
Off |
MRS mode enabled | SW1/4 |
On |
|
» | Parity check disabled | SW1/5 |
Off |
Parity check enabled | SW1/5 |
On |
|
» | DDS data compression mode disabled | SW1/6 |
Off |
DDS pass through mode enabled | SW1/6 |
On |
|
» | Factory configured - do not alter | SW1/7 |
Off |
» | Self test disabled | SW1/8 |
Off |
Self test enabled | SW1/8 |
On |
|
» | Drive mounted horizontaly | SW2/1 |
Off |
Drive mounted verticaly | SW2/1 |
On |
|
» | Automatic insertion of first cartridge enabled | SW2/2 |
On |
Automatic insertion of first cartridge disabled | SW2/2 |
Off |
|
» | Factory configured - do not alter | SW2/3 |
Unidentified |
» | Factory configured - do not alter | SW2/4 |
Unidentified |
» | Continuous cycle disabled | SW3/3 |
Off |
Continuous cycle enabled | SW3/3 |
On |
|
» | Display intensity high | SW3/4 |
On |
Display intensity normal | SW3/4 |
Off |
|
» | Self-test sequence disabled | SW3/5 |
Off |
Self-test sequence enabled | SW3/5 |
On |
|
» | Factory configured - do not alter | SW3/6 |
Unidentified |
» | Factory configured - do not alter | SW3/7 |
Unidentified |
EXTERNAL SCSI ID SELECTION |
||||
SCSI ID |
JP1/1 |
JP1/2 |
JP1/3 |
|
» | 0 |
Open |
Open |
Open |
1 |
Closed |
Open |
Open |
|
2 |
Open |
Closed |
Open |
|
3 |
Closed |
Closed |
Open |
|
4 |
Open |
Open |
Closed |
|
5 |
Closed |
Open |
Closed |
|
6 |
Open |
Closed |
Closed |
|
7 |
Closed |
Closed |
Closed |
|
Note: If SCSI ID is set using SW1/1 - SW1/3, then the external SCSI ID (JP1) must be set to 0. |
SCSI ID SELECTION |
||||
SCSI ID |
SW1/1 |
SW1/2 |
SW1/3 |
|
» | 0 |
Open |
Open |
Open |
1 |
Closed |
Open |
Open |
|
2 |
Open |
Closed |
Open |
|
3 |
Closed |
Closed |
Open |
|
4 |
Open |
Open |
Closed |
|
5 |
Closed |
Open |
Closed |
|
6 |
Open |
Closed |
Closed |
|
7 |
Closed |
Closed |
Closed |
|
Note: If SCSI ID is set using SW1/1 - SW1/3, then the external SCSI ID (JP1) must be set to 0. |
LANGUAGE SELECTION |
|||
Language |
SW3/1 |
SW3/2 |
|
» | English | Off |
Off |
French | Off |
On |
|
German | On |
Off |
|
Spanish | On |
On |
MANUFACTURERS RECOMMENDED MEDIA |
||
Tape |
Capacity Without Compression |
Capacity With Compression |
60 meter DAT single cartridge | 1.3 GB | 2.6 GB |
90 meter DAT single cartridge | 2.0 GB | 4 GB |
60 meter DAT 4-cartridge | 5.2 GB | 10.4 GB |
90 meter DAT 4-cartridge | 8.0 GB | 16.0 GB |
120 meter MP+ single cartridge | N/A | 4.0 GB |
120 meter MP+ 4-cartridge | N/A |
16.0 GB |
120 meter DAT 12-cartridge | N/A |
96 GB |