TANDBERG DATA
SLR6 (INTERNAL)
Device Type |
Internal Tape Drive |
Interface |
SCSI-2 Fast/Wide |
Format |
SLR6 |
Sustained Transfer Rate |
1.2 MBPS |
Size |
5.25 in. half height |
View |
Top |
CONNECTIONS |
|||
Function |
Label |
Function |
Label |
Power connector |
CN1 |
SCSI-2 F/W interface |
CN2 |
USER CONFIGURABLE SETTINGS |
|||
Setting |
Label |
Position |
|
» |
Termination enabled |
JP1 |
Pins 31 & 32 closed |
Termination disabled |
JP1 |
Pins 31 & 32 open |
|
» |
Parity check disabled |
JP1 |
Pins 19 & 20 open |
Parity check enabled |
JP1 |
Pins 19 & 20 closed |
DRIVE SELECT ID |
||||
Drive ID |
JP1/21 & 22 |
JP1/23 & 24 |
JP1/25 & 26 |
JP1/27 & 28 |
0 |
Open |
Open |
Open |
Open |
1 |
Closed |
Open |
Open |
Open |
2 |
Open |
Closed |
Open |
Open |
3 |
Closed |
Closed |
Open |
Open |
4 |
Open |
Open |
Closed |
Open |
5 |
Closed |
Open |
Closed |
Open |
6 |
Open |
Closed |
Closed |
Open |
7 |
Closed |
Closed |
Closed |
Open |
8 |
Open |
Open |
Open |
Closed |
9 |
Closed |
Open |
Open |
Closed |
10 |
Open |
Closed |
Open |
Closed |
11 |
Closed |
Closed |
Open |
Closed |
12 |
Open |
Open |
Closed |
Closed |
13 |
Closed |
Open |
Closed |
Closed |
14 |
Open |
Closed |
Closed |
Closed |
15 |
Closed |
Closed |
Closed |
Closed |
MANUFACTURERS RECOMMENDED MEDIA |
||
Tape |
Capacity Without Compression |
Capacity With Compression |
DC 9200/Magnus 2.0 |
2.0GB |
4.0GB |
DC 9250/Magnus 2.5 |
2.5GB |
5.0GB |
SLR5 |
4.0GB |
8.0GB |
SLR6 |
12.0GB |
24.0GB |
FRONT PANEL
DIAGNOSTIC LED(S) |
|||
Condition |
LED1 (Green) |
LED2 (Green) |
LED3 (Amber) |
LED test during power up |
On |
On |
On |
Unit is in power up self test or diagnostic tape activity |
Blinking |
Off |
Off |
Tape is not loaded |
Off |
Off |
Off |
Tape is not loaded; cleaning needed |
Off |
Off |
On |
Tape is loaded; no activity |
On |
Off |
Off |
Tape is loaded; tape is moving or tape is loading/unloading |
On |
Blinking |
Off |
Tape is loaded; no activity; cleaning needed |
On |
Off |
On |
Tape is loaded; tape is moving; cleaning needed |
On |
Blinking |
On |
Unit is in cleaning mode |
Off |
Blinking |
On |
Tape or drive failure |
Off |
Off |
Blinking |
DIAGNOSTIC LED(S) DURING FLASH UPGRADE |
|||
Condition |
LED1 (Green) |
LED2 (Green) |
LED3 (Amber) |
Performing EEC and header check on data buffer code; or code is executed from RAM |
On |
Off |
Off |
FLASH update is being transferred to RAM |
On |
Off |
On |
Old code is being erased |
Off |
On |
On |
FLASH programming in progress |
Blinking |
On |
On |
FLASH programming is complete; unit is ready |
Off |
On |
Off |
Error has occurred; re-initialize drive |
On |
On |
On |