TANDBERG DATA

SLR6 (INTERNAL)

Device Type

Internal Tape Drive

Interface

SCSI-2 Fast/Wide

Format

SLR6

Sustained Transfer Rate

1.2 MBPS

Size

5.25 in. half height

View

Top

CONNECTIONS

Function

Label

Function

Label

Power connector

CN1

SCSI-2 F/W interface

CN2


USER CONFIGURABLE SETTINGS

Setting

Label

Position

»

Termination enabled

JP1

Pins 31 & 32 closed

 

Termination disabled

JP1

Pins 31 & 32 open

»

Parity check disabled

JP1

Pins 19 & 20 open

 

Parity check enabled

JP1

Pins 19 & 20 closed


DRIVE SELECT ID

Drive ID

JP1/21 & 22

JP1/23 & 24

JP1/25 & 26

JP1/27 & 28

0

Open

Open

Open

Open

1

Closed

Open

Open

Open

2

Open

Closed

Open

Open

3

Closed

Closed

Open

Open

4

Open

Open

Closed

Open

5

Closed

Open

Closed

Open

6

Open

Closed

Closed

Open

7

Closed

Closed

Closed

Open

8

Open

Open

Open

Closed

9

Closed

Open

Open

Closed

10

Open

Closed

Open

Closed

11

Closed

Closed

Open

Closed

12

Open

Open

Closed

Closed

13

Closed

Open

Closed

Closed

14

Open

Closed

Closed

Closed

15

Closed

Closed

Closed

Closed


MANUFACTURERS RECOMMENDED MEDIA

Tape

Capacity Without Compression

Capacity With Compression

DC 9200/Magnus 2.0

2.0GB

4.0GB

DC 9250/Magnus 2.5

2.5GB

5.0GB

SLR5

4.0GB

8.0GB

SLR6

12.0GB

24.0GB

FRONT PANEL

DIAGNOSTIC LED(S)

Condition

LED1

(Green)

LED2

(Green)

LED3

(Amber)

LED test during power up

On

On

On

Unit is in power up self test or diagnostic tape activity

Blinking

Off

Off

Tape is not loaded

Off

Off

Off

Tape is not loaded; cleaning needed

Off

Off

On

Tape is loaded; no activity

On

Off

Off

Tape is loaded; tape is moving or tape is loading/unloading

On

Blinking

Off

Tape is loaded; no activity; cleaning needed

On

Off

On

Tape is loaded; tape is moving; cleaning needed

On

Blinking

On

Unit is in cleaning mode

Off

Blinking

On

Tape or drive failure

Off

Off

Blinking


DIAGNOSTIC LED(S) DURING FLASH UPGRADE

Condition

LED1

(Green)

LED2

(Green)

LED3

(Amber)

Performing EEC and header check on data buffer code; or code is executed from RAM

On

Off

Off

FLASH update is being transferred to RAM

On

Off

On

Old code is being erased

Off

On

On

FLASH programming in progress

Blinking

On

On

FLASH programming is complete; unit is ready

Off

On

Off

Error has occurred; re-initialize drive

On

On

On